Prometheus Metrics
PVC Chonker exports comprehensive Prometheus metrics for monitoring and alerting. All metrics use the pvcchonker namespace with appropriate subsystems.
Resizer Metrics
Success/Failure Counters
pvcchonker_resizer_success_resize_total{persistentvolumeclaim, namespace}- Successful PVC expansionspvcchonker_resizer_failed_resize_total{persistentvolumeclaim, namespace, reason}- Failed PVC expansions with reasonpvcchonker_resizer_threshold_reached_total{persistentvolumeclaim, namespace}- Times threshold was reachedpvcchonker_resizer_limit_reached_total{persistentvolumeclaim, namespace}- Times max size limit was reached
Operational Counters
pvcchonker_resizer_cooldown_skipped_total{persistentvolumeclaim, namespace}- PVCs skipped due to cooldownpvcchonker_resizer_resize_in_progress_total{persistentvolumeclaim, namespace}- PVCs skipped due to ongoing resizepvcchonker_resizer_loop_seconds_total- Total seconds spent in reconciliation loops
Client Metrics
Kubernetes API Client
pvcchonker_kubernetes_client_requests_total{operation, status}- Total API requests by operation and statuspvcchonker_kubernetes_client_fail_total{operation}- Failed API requests by operation
Kubelet Client
pvcchonker_kubelet_client_requests_total{status}- Total kubelet requests by statuspvcchonker_kubelet_client_fail_total- Failed kubelet requestspvcchonker_kubelet_client_response_time_seconds- Kubelet response time histogram
Operational Metrics
System Status
pvcchonker_last_reconciliation_timestamp_seconds- Timestamp of last reconciliationpvcchonker_reconciliation_status{status}- Last reconciliation status (success/failure)pvcchonker_managed_pvcs_total- Total number of managed PVCs
PVC Status
pvcchonker_pvc_usage_percent{persistentvolumeclaim, namespace}- Current PVC storage usage percentagepvcchonker_pvc_capacity_bytes{persistentvolumeclaim, namespace}- Current PVC capacity in bytespvcchonker_pvc_inodes_usage_percent{persistentvolumeclaim, namespace}- Current PVC inode usage percentagepvcchonker_pvc_inodes_total{persistentvolumeclaim, namespace}- Total inodes available in PVC
Note: Inode metrics are only available for volumes that expose inode statistics via kubelet. ext3/ext4 filesystems have fixed inode counts that don't increase with volume expansion.
Failure Reasons
The reason label in pvcchonker_resizer_failed_resize_total includes:
storage_class_not_expandable- Storage class doesn't allow expansionmetrics_not_found- Volume metrics unavailableexpansion_failed- PVC update operation failed
Example Queries
Alert on High Failure Rate
rate(pvcchonker_resizer_failed_resize_total[5m]) > 0.1
Monitor PVC Usage
# Storage usage
pvcchonker_pvc_usage_percent > 80
# Inode usage (filesystem-dependent)
pvcchonker_pvc_inodes_usage_percent > 80
# Alert on inode pressure for ext3/ext4 (expansion won't help)
pvcchonker_pvc_inodes_usage_percent > 90 and pvcchonker_pvc_inodes_total > 0
Track Expansion Success Rate
rate(pvcchonker_resizer_success_resize_total[5m]) /
(rate(pvcchonker_resizer_success_resize_total[5m]) + rate(pvcchonker_resizer_failed_resize_total[5m]))
Monitor Kubelet Connectivity
rate(pvcchonker_kubelet_client_fail_total[5m]) > 0
Comparison with TopoLVM PVC Autoresizer
Our metrics provide equivalent or superior coverage compared to TopoLVM:
| TopoLVM Metric | PVC Chonker Equivalent | Enhancement |
|---|---|---|
pvcautoresizer_success_resize_total | pvcchonker_resizer_success_resize_total | Same functionality |
pvcautoresizer_failed_resize_total | pvcchonker_resizer_failed_resize_total | Added failure reasons |
pvcautoresizer_loop_seconds_total | pvcchonker_resizer_loop_seconds_total | Same functionality |
pvcautoresizer_limit_reached_total | pvcchonker_resizer_limit_reached_total | Same functionality |
pvcautoresizer_kubernetes_client_fail_total | pvcchonker_kubernetes_client_fail_total | Added operation labels |
pvcautoresizer_metrics_client_fail_total | pvcchonker_kubelet_client_fail_total | Renamed for clarity |
| - | pvcchonker_resizer_threshold_reached_total | New: Track threshold events |
| - | pvcchonker_resizer_cooldown_skipped_total | New: Track cooldown behavior |
| - | pvcchonker_resizer_resize_in_progress_total | New: Track concurrent resizes |
| - | pvcchonker_pvc_usage_percent | New: Real-time storage usage monitoring |
| - | pvcchonker_pvc_capacity_bytes | New: Capacity tracking |
| - | pvcchonker_pvc_inodes_usage_percent | New: Real-time inode usage monitoring |
| - | pvcchonker_pvc_inodes_total | New: Inode capacity tracking |
| - | pvcchonker_kubelet_client_response_time_seconds | New: Performance monitoring |
Grafana Dashboard
A sample Grafana dashboard configuration is available in examples/grafana-dashboard.json with panels for:
- Expansion success/failure rates
- PVC usage trends
- System health indicators